   1. The hot air stenter entrance frame and width limiter can help the cloth guide to unfold and correct the cloth, and the cloth can be inserted in high and low positions;

  2. The composite center corrector (cloth guide) has the function of guiding and straight-tracking correction;

  3. Water pressure and sizing in the sizing machine (rolling car);

  4. Speed ​​compensation device (displacement detection wheel), which can control the tension between the sizing machine and the hot air stenter;

  5. Thread gauze correction product, which can correct the thread yarn or thread arc in the cloth area;

  6. The central control panel, which concentrates all-electric adjustment functions on the top of the entrance box, covering 95% of the operational functions of the whole machine;

  7. Selvedge and selvage tracker, responsible for the unfolding of selvage and selvedge tracking function before stitching;

  8. Entrance box and needle feeding device on retractable code;

  9. Needle/clamp chain and track, use needle plate or splint to transport cloth area into the oven for drying;

  10. Hot air circulating air box, hot air circulating windmill, heat exchanger, drying or setting cloth area;

  11. Width adjustment machine, which can adjust the width of the cloth;

  12. Exhaust system;

  13. Cloth discharging device or cloth roll, there are two kinds of cloth discharging methods: cloth discharging and roll cloth.